عرض مسار لوحة الدارات


Work out minimum trace width, cross-section area and trace resistance.

أدخل القيم واضغط على احسب. ستظهر النتائج أدناه.

أدخل القيم:
°C
°C
النتائج:
mil²

About this calculator

The pcb trace width calculator (ipc-2221) calculator works out minimum trace width, cross-section area, trace resistance from current, allowed temperature rise, copper thickness, layer, used in circuit design and electrical engineering work. Enter your values and it computes the result instantly.

What you need

  • Current; the unit box converts between µA, mA, A.
  • Allowed temperature rise in °C.
  • Copper thickness.
  • Layer.
  • Trace length (optional); the unit box converts between mm, cm, m, in, ft.
  • Ambient temperature in °C.

Formula

Minimum trace width = amil/tmil*2.54e-5.

Cross-section area = amil.

Trace resistance = rho*len/am2.

Where amil = (i/(k*dt^0.44))^(1/0.725); tmil = oz*1.378; am2 = amil*(2.54e-5)^2; rho = 1.72e-8*(1+0.00393*(ta+dt-20)).

Worked example

With current 10 A, allowed temperature rise 25 °C, copper thickness 2, layer 10, trace length (optional) 2 mm, ambient temperature 25 °C, the calculator gives minimum trace width = 0.05144 mil; cross-section area = 0.1418 mil²; trace resistance = 420.4351 mΩ; voltage drop = 4,204.35 mV; power loss = 42,043.51 mW.

How to read the result

The main result is the minimum trace width, shown after you click Calculate; the copy button next to it copies the value. Additional results: cross-section area, trace resistance, voltage drop.