Sizing a pump comes down to two numbers: how much head it must develop and how much power it needs to do that. This guide shows how to find both for a water pumping duty, step by step, with units and a worked example you can repeat with your own data.
Assumptions and symbols
- Incompressible, single-phase liquid (water in the example), steady flow.
- Q = flow rate in m³/s (divide m³/h by 3600).
- ρ = liquid density in kg/m³ (about 998 for water at 20 °C).
- g = 9.81 m/s².
- H = total dynamic head (TDH) in metres of liquid column.
- v = mean velocity in the pipe in m/s, D = inside diameter in m, L = pipe length in m.
- f = Darcy friction factor (dimensionless), K = loss coefficient of a fitting or valve (dimensionless).
Step 1: Total dynamic head
Head is energy per unit weight of liquid. The pump must supply the difference in energy between the discharge point and the suction point, plus all the losses in between:
H = Hstatic + Hpressure + Hvelocity + Hfriction + Hminor
- Static head Hstatic = height of the discharge liquid surface (or outlet) above the suction liquid surface, in m.
- Pressure head Hpressure = (p2 − p1) / (ρg), where p is the pressure acting on the liquid surface at each end, in Pa. It is zero when both tanks are open to the atmosphere.
- Velocity head Hvelocity = (v22 − v12) / (2g). It is usually negligible when both ends are large tanks.
- Friction head Hfriction = f · (L/D) · v2/(2g) (Darcy-Weisbach equation).
- Minor losses Hminor = ΣK · v2/(2g) for bends, valves, entrances and exits.
Step 2: Power
- Hydraulic power (power given to the liquid): Ph = ρ · g · Q · H, in watts.
- Shaft power (power the pump takes from the motor): Pshaft = Ph / ηpump.
- Electrical input: Pel = Pshaft / ηmotor.
Efficiencies are fractions (0.70 for 70 %). Read the pump efficiency from the manufacturer's curve at your duty point, not from the best-efficiency point.
Worked example
Duty: pump water at 20 °C (ρ = 998 kg/m³) from an open tank to another open tank whose water level is 25 m higher. Flow 36 m³/h. The pipe is 100 mm inside diameter and 150 m long in total, with f = 0.02 and fittings totalling ΣK = 6. Assume pump efficiency 70 % and motor efficiency 90 %.
- Flow: Q = 36 / 3600 = 0.010 m³/s.
- Pipe area: A = π × 0.12 / 4 = 0.007854 m². Velocity: v = 0.010 / 0.007854 = 1.273 m/s.
- Velocity head: v2/(2g) = 1.2732 / 19.62 = 0.0826 m.
- Friction head: 0.02 × (150 / 0.1) × 0.0826 = 30 × 0.0826 = 2.48 m.
- Minor losses: 6 × 0.0826 = 0.50 m.
- Pressure head = 0 (both tanks open) and velocity head difference = 0 (tank surfaces).
- TDH = 25 + 2.48 + 0.50 = 27.97 m.
- Hydraulic power: Ph = 998 × 9.81 × 0.010 × 27.97 = 2,739 W = 2.74 kW.
- Shaft power: 2.74 / 0.70 = 3.91 kW.
- Electrical input: 3.91 / 0.90 = 4.35 kW.
For motor selection, many designers add a margin of 10 to 20 % on shaft power. With 15 %: 3.91 × 1.15 = 4.50 kW, so the next standard motor rating above it (5.5 kW) would be chosen. Follow the margin rules of your own standard or specification.
Quick rule of thumb
For water, Ph (kW) ≈ Q (m³/h) × H (m) / 367. Check: 36 × 27.97 / 367 = 2.74 kW, matching the result above.
Limitations
- The friction factor f depends on Reynolds number and pipe roughness. Take it from the Moody chart or the Colebrook equation rather than assuming 0.02 on a real design.
- Viscous liquids, slurries and gas-laden liquids need correction factors for head, flow and efficiency.
- The result is the head at one duty point. Check the pump curve and the system curve intersect there.
- Check NPSH available against NPSH required to avoid cavitation. This article does not cover it.
- This is an educational, preliminary calculation. Final pump and motor selection should be confirmed by a qualified engineer or the pump supplier.
Try it with your numbers
Use the Pump Total Dynamic Head Calculator to find the head, then the Centrifugal Pump Power Calculator to get hydraulic, shaft and motor power and the running cost. See also Series and Parallel Pump Operation if you plan to run more than one pump.