BTU Calculator (Room Air Conditioner Sizing)
Air conditioner size in BTU per hour and tons of cooling from the room area, ceiling height, sun exposure, occupants and whether it is a kitchen.
Enter the room size and conditions.
How it works
Base load = room area × 20 BTU/hr per ft² (ENERGY STAR rule of thumb), adjusted: +10% for heavy sun, −10% for heavy shade, +600 BTU/hr per person beyond two, +4,000 BTU/hr for a kitchen, and scaled for ceilings over 8 ft.
- Common room AC sizes: 5,000 BTU (up to 150 ft²), 8,000 (350), 12,000 (550), 14,000 (700); 12,000 BTU/hr = 1 ton.
- Oversizing short-cycles the compressor and leaves the room clammy - close is better than big.
- Poor insulation, many windows or a hot top floor push the real load up; treat the result as a floor.
Rule-of-thumb sizing for single rooms. Whole-house systems need a Manual J load calculation by an HVAC professional.