Distillation Stages Calculator (Fenske-Underwood-Gilliland)


Shortcut design of a binary distillation column: minimum stages by Fenske, minimum reflux by Underwood (saturated liquid feed), and actual stages by the Gilliland correlation.

Mole fractions of the light component. Feed assumed saturated liquid (q = 1).

Enter your values:
Results:

How it works

  • Fenske: Nₗᵢₙ = ln[(xა/(1−xა))((1−xე)/xე)] / ln α (total reflux, includes the reboiler).
  • Underwood for saturated liquid feed: Rₗᵢₙ = [xა/xₛ − α(1−xა)/(1−xₛ)] / (α − 1).
  • Gilliland (Eduljee form): with X = (R−Rₗᵢₙ)/(R+1), Y = (N−Nₗᵢₙ)/(N+1) = 1 − exp[((1+54.4X)/(11+117.2X)) × (X−1)/√X].

Worked example

xა = 0.95, xე = 0.05, xₛ = 0.5, α = 2.4, R = 1.5 Rₗᵢₙ. Nₗᵢₙ = ln(19 × 19)/ln 2.4 = 5.89/0.875 = 6.7 stages. Rₗᵢₙ = (1.9 − 2.4 × 0.1)/1.4 = 1.19, R = 1.78. X = 0.283, Y = 0.439, so N = (Nₗᵢₙ + Y)/(1 − Y) = 12.7, about 13 theoretical stages.

Assumptions and limitations

  • Binary mixture with constant relative volatility.
  • Saturated liquid feed (q = 1); for other feeds the Underwood root changes.
  • Shortcut accuracy is about ±10%; verify with a rigorous stage-by-stage method before detailed design.