EV Battery Pack Calculator


Pack sizing from the cell level: series count sets voltage, parallel count sets capacity, and together with the vehicle consumption they set the range.

Ns cells in series per string, Np strings in parallel.

Enter your values:
Results:

How it works

Cells in series add voltage, cells in parallel add capacity:

Vₚₐ₊ₖ = Nₛ × V₊ₑₗₗ, Cₚₐ₊ₖ = Nₚ × C₊ₑₗₗ, E = V × C

Usable energy is the total times the usable window (to protect cycle life, packs use about 90-95%), and range = usable energy / consumption.

Worked example

96 cells in series, 4 in parallel, 3.7 V 4.8 Ah cells: pack 355 V, 19.2 Ah, 6.82 kWh. At 90% usable and 150 Wh/km, range = 6.14/0.150 = 41 km.

Assumptions and limitations

  • Nominal cell voltage (3.6-3.7 V for NMC/LCO, 3.2 V for LFP); the pack swings roughly ±15% over the charge window.
  • Range ignores temperature, driving style, HVAC and aging.
  • Cell mismatch and the BMS limit usable capacity further in real packs.