Gas Scrubber Sizing Calculator
Preliminary sizing of a packed or spray gas scrubber: column diameter from the gas flow and design superficial velocity, scrubbing liquor rate from the liquid-to-gas ratio, and removal check.
Gas flow at actual conditions. Design velocity 1-2.5 m/s for packed towers.
How it works
Diameter follows from the design gas velocity (typically 1-2.5 m/s for packed towers, 60-80% of flooding):
D = √(4Q/(πv)).
The liquor rate is set by the liquid-to-gas ratio L/G (typically 0.5-2 L/m³ for water scrubbing), and the removal efficiency follows the inlet and target outlet concentrations.
Worked example
Gas 10,000 m³/h at v = 1.5 m/s: D = √(4 × 2.778/(π × 1.5)) = 1.535 m, choose 1.6 m. L/G = 1.0 L/m³ gives 10 m³/h of liquor. Inlet 500 ppm, target 25 ppm: removal 95%.
Assumptions and limitations
- Preliminary sizing only; mass-transfer (NTU/HTU) design sets the packing height.
- For reactive scrubbing the liquor rate is set by chemistry, not only L/G.
- Check pressure drop and entrainment at the chosen velocity.