Mold Cavity Pressure and Clamp Force Calculator
Force balance for an injection mold: clamp force needed from the projected area, number of cavities and mean cavity pressure, plus the reverse check of allowable cavity pressure for a given machine.
Projected area of ONE cavity including its share of the runner.
How it works
The melt pressure acting on the projected area of the cavities tries to blow the mold open; the clamp must hold it shut with margin:
F = P₊ × Aₓ × n × SF
where F is the clamp force, P₊ the mean cavity pressure, Aₓ the projected area of one cavity including its runner, n the number of cavities and SF a safety factor (1.1-1.2 typical).
Worked example
Part projected area 80 cm², 4 cavities, mean cavity pressure 400 bar, safety factor 1.15: opening force = 40 MPa × 80×10⁻⁴ m² × 4 = 1280 kN, with margin 1472 kN = 150 tf, so a 150-ton machine is the floor.
Assumptions and limitations
- Mean cavity pressure is 30-80% of the injection pressure depending on material, wall thickness and flow length; thin long parts sit high in the range.
- Include the cold runner projected area when the runner stays on the parting line.
- This is a force balance only; flash, platen deflection and mold wear add their own limits.