Force balance for an injection mold: clamp force needed from the projected area, number of cavities and mean cavity pressure, plus the reverse check of allowable cavity pressure for a given machine.

Projected area of ONE cavity including its share of the runner.

Enter your values:
Results:

How it works

The melt pressure acting on the projected area of the cavities tries to blow the mold open; the clamp must hold it shut with margin:

F = P₊ × Aₓ × n × SF

where F is the clamp force, P₊ the mean cavity pressure, Aₓ the projected area of one cavity including its runner, n the number of cavities and SF a safety factor (1.1-1.2 typical).

Worked example

Part projected area 80 cm², 4 cavities, mean cavity pressure 400 bar, safety factor 1.15: opening force = 40 MPa × 80×10⁻⁴ m² × 4 = 1280 kN, with margin 1472 kN = 150 tf, so a 150-ton machine is the floor.

Assumptions and limitations

  • Mean cavity pressure is 30-80% of the injection pressure depending on material, wall thickness and flow length; thin long parts sit high in the range.
  • Include the cold runner projected area when the runner stays on the parting line.
  • This is a force balance only; flash, platen deflection and mold wear add their own limits.