Sedimentation Tank Design Calculator


Preliminary sizing of a rectangular primary or secondary settling tank: surface area from the overflow rate, volume and detention time from the depth, and weir loading check.

Overflow rate and weir loading are the controlling checks. Depth 2.5-4 m, L/W about 4.

Enter your values:
Results:

How it works

Surface area is set by the surface overflow rate (SOR): A = Q/SOR. Typical SOR is 25-60 m³/m²d for primary and 16-32 m³/m²d for secondary clarifiers. With side water depth (2.5-4 m) the detention time is V/Q, and the weir loading Q/Lₕ should stay below about 250 m³/m of weir per day.

Plan dimensions assume a length-to-width ratio (default 4:1): W = √(A/ratio), L = ratio × W.

Worked example

Q = 10,000 m³/d, SOR = 30 m³/m²d: A = 333 m². Ratio 4: W = 9.1 m, L = 36.5 m. Depth 3 m: V = 1000 m³, detention = 2.4 h. Weir 36.5 m (one effluent launder): loading = 274 m³/m/d, so add a second weir.

Assumptions and limitations

  • Ideal settling; short-circuiting lowers real performance.
  • Sludge storage volume is additional to the clarified depth.
  • Check against the local design code (CPHEEO/10-state standards).