Two-Way Slab Design Calculator (IS 456)


Factored moments and required tension steel for a two-way reinforced concrete slab per IS 456. Enter the spans, loads and the moment coefficients from the code table for your edge conditions.

Spans centre to centre. Take moment coefficients αx and αy from IS 456 Table 26 for your edge case.

Enter your values:
Results:

How it works

For a slab supported on all four edges with lₛ/lₓ ≤ 2, design moments per metre width are Mₓ = αₓ w lₓ² and Mₛ = αₛ w lₓ², where w is the factored load and the coefficients α come from IS 456 Table 26 for the edge conditions. Required steel uses the singly reinforced working expression Aₛₜ = M/(0.87 fₛ · 0.9d), with d = D − cover − bar/2, checked against minimum steel 0.12% of gross area for Fe 415/500.

Interior-panel coefficients (Table 26) at lₛ/lₓ = 1.0, 1.5, 2.0: αₓ = 0.056, 0.089, 0.112 (negative) and 0.062, 0.100, 0.124 approx for short span; use the code table for your actual case and interpolate.

Worked example

lₓ = 4 m, lₛ = 5 m, D = 150 mm, cover 20 mm, 10 mm bars, Fe 500, finishes 1.5 kN/m², live 3 kN/m², αₓ = 0.062, αₛ = 0.040. Self weight = 3.75 kN/m², w₝ = 1.5 × (3.75+1.5+3) = 12.38 kN/m². d = 150 − 20 − 5 = 125 mm. Mₓ = 0.062 × 12.38 × 16 = 12.28 kNm/m, Aₛₜ = 12.28e6/(0.87 × 500 × 112.5) = 251 mm²/m; minimum = 180 mm²/m, so 251 governs.

Assumptions and limitations

  • Coefficient method for rectangular panels; lₑ/lₓ above 2 is one-way action.
  • You must pick the coefficients from IS 456 Table 26 for the actual edge conditions.
  • Checks for shear, deflection (span/effective depth) and crack width are separate and still required.