Welding Heat Input Calculator
Arc energy per unit weld length from voltage, current, travel speed and the process thermal efficiency, in the units welding procedures (WPS) are written in.
Travel speed in mm/s (60 mm/min = 1 mm/s). Mean current for pulsed processes.
How it works
Heat input controls cooling rate, HAZ hardness and distortion:
HI = η × V × I / v
with V in volts, I in amps, v the travel speed. With v in mm/s the result is J/mm; divide by 1000 for kJ/mm. Thermal efficiency η: SMAW 0.8, GMAW/MIG 0.8, SAW 0.9-1.0, GTAW/TIG 0.6 (AWS A3.0 / EN 1011 guidance).
Worked example
GMAW at 26 V, 220 A, travel 5 mm/s, η = 0.8: HI = 0.8 × 26 × 220 / 5 = 915 J/mm = 0.92 kJ/mm (23.2 kJ/in).
Assumptions and limitations
- Use the efficiency the governing code specifies; some standards (ASME IX) use η = 1.
- Pulsed processes need the mean current, not the peak.
- Cooling rate also depends on plate thickness and preheat; heat input alone does not set the microstructure.