Terzaghi Bearing Capacity Calculator


The original Terzaghi (1943) bearing capacity equations for shallow footings, with both general shear and local shear (reduced strength) modes, for strip, square and circular foundations.

Enter soil strength, unit weight and footing geometry.

Geben Sie Ihre Werte ein:
Ergebnisse:

How it works

Terzaghi's equations: strip q(ult) = cN(c) + γD(f)N(q) + 0.5γBN(γ); square: 1.3cN(c) + γD(f)N(q) + 0.4γBN(γ); circular: 1.3cN(c) + γD(f)N(q) + 0.3γBN(γ). Factors: N(q) = eπtanφtan²(45+φ/2), N(c) = (N(q)−1)cotφ, N(γ) = 1.8(N(q)−1)tan(1.4φ) (Kumbhojkar fit). Local shear mode reduces strength to c' = 2c/3 and tanφ' = (2/3)tanφ before computing the factors.

  • General shear for dense sands and stiff clays; local shear for loose sands (φ < ~28°) and soft clays.
  • Assumes vertical centred load, horizontal base, no water-table correction.
  • φ = 0 gives the classic N(c) = 5.7 for undrained clay.

Preliminary design. Confirm with site investigation; compare with the Meyerhof calculator (which adds depth and inclination factors).