Condensation Risk and Dew Point Calculator


Will moisture condense on your wall or window? Computes the dew point of the room air (Magnus formula), the inner surface temperature of the construction from its U-value, and the margin between them.

Enter indoor conditions, outdoor temperature and the construction U-value.

Introduzca los valores:

Wall ~0.3-2.0, single glazing ~5.8, double ~2.8 W/m²K.

Resultados:

How it works

Dew point from the Magnus formula: T(dp) = 243.12·γ/(17.62−γ) with γ = ln(RH/100) + 17.62·T/(243.12+T). The inner surface temperature of a construction is T(s) = T(i) − U·R(si)·(T(i)−T(o)). Condensation starts when T(s) drops to T(dp).

  • Thermal bridges (lintels, corners, slab edges) have locally higher U - check them with the thermal bridge calculator or a higher U here.
  • The critical RH tells you how much you can humidify before the surface gets wet.
  • Interstitial condensation inside the construction needs a Glaser/vapour-diffusion check, not this surface method.

Surface assessment per the standard steady-state method. Magnitudes per ISO 13788 conventions.