ギアポンプサイズ


Estimate an external gear pump's delivery in GPM at 1200 RPM from the gear dimensions.

Select units for each gear dimension. The formula uses inches internally. The result is the approximate pump delivery at 1200 RPM.

数値を入力:
計算結果:

How it works

GPM at 1200 RPM = width × center distance × (outer diameter − center distance) ÷ 70 × 1200, with all dimensions in inches.

Example

Gear OD 4 in, width 1 in, center distance 3 in: 1 × 3 × (4 − 3) ÷ 70 × 1200 ≈ 51.4 GPM.

Note

This is the site's original rule-of-thumb from /mech/gear pump size.htm; it is an approximation for standard external gear pumps, not a substitute for the pump maker's displacement data.