サレンキー・バタワース・ローパスフィルター


Work out capacitor Cb and capacitor Ca (= 2 × Cb).

数値を入力して「計算」をクリックしてください。結果が下に表示されます。

R を選ぶ

数値を入力:
計算結果:

About this calculator

The sallen-key active butterworth low pass filter calculator works out capacitor Cb, capacitor Ca (= 2 × Cb) from cut-off frequency, resistors Ra = Rb, used in circuit design and electrical engineering work. Enter your values and it computes the result instantly.

It has 2 modes: Choose R, Choose Cb. Pick the tab for the quantity you want.

What you need

  • Cut-off frequency; the unit box converts between Hz, kHz, MHz, GHz.
  • Resistors Ra = Rb; the unit box converts between Ω, kΩ, MΩ.

Formula

Capacitor Cb = 1/(2*pi*sqrt(2)*f*r).

Capacitor Ca (= 2 × Cb) = 2/(2*pi*sqrt(2)*f*r).

Worked example

With cut-off frequency 1,000.00 kHz, resistors Ra = Rb 10 kΩ in Choose R mode, the calculator gives capacitor Cb = 0.01125 nF; capacitor Ca (= 2 × Cb) = 0.02251 nF.

How to read the result

The main result is the capacitor Cb, shown after you click Calculate; the copy button next to it copies the value. Additional results: capacitor Ca (= 2 × Cb).