Culvert Hydraulic Capacity Calculator


Estimate the capacity of a circular culvert under three conditions: inlet control (submerged orifice), outlet control (full-barrel Manning with entrance and friction losses), and open-channel full flow - the lowest governs.

Enter culvert geometry, slope, roughness and headwater depth above the inlet invert.

값을 입력하세요:

Concrete 0.012-0.013, corrugated metal 0.022-0.024.

Projecting 0.9, square edge 0.5, bevelled 0.2.

결과:

How it works

Inlet control (submerged, HW > D): Q = C(d)·A·√(2g(HW−D/2)) with C(d) = 0.6. Outlet control (full barrel): Q = A·√(2gH/(1+K(e)+K(n))) with H = HW + S·L − D (tailwater at crown) and Manning loss K(n) = 2gn²L/R4/3. Open channel: full-flow Manning Q = (1/n)AR2/3S1/2. The lowest value governs.

  • Unsubmerged inlet (HW < ~1.2D) behaves as a weir - this tool's inlet equation is conservative there; the open-channel value usually governs then.
  • Tailwater above the crown submerges the outlet: the outlet equation covers it; below crown, capacity is between outlet and open-channel values.
  • Check outlet velocity against scour limits for the receiving channel.

Screening estimate per FHWA HDS-5 concepts. Design with the FHWA nomographs or HY-8 for the full inlet/outlet performance curve.