Temperatura do dissipador


Work out maximum power and heat flow.

Insira os valores e clique em Calcular. Os resultados aparecerão abaixo.

Potência máxima

Insira os valores:
°C
°C
°C/W
°C/W
°C/W
Resultados:
BTU/h

About this calculator

The heat sink temperature calculator works out maximum power, heat flow from ambient temperature Ta, junction temperature Tj, junction-to-case θjc, case-to-heat-sink θcs, used in electronics and circuit design. Enter your values and it computes the result instantly.

It has 2 modes: Maximum power, Junction temperature. Pick the tab for the quantity you want.

What you need

  • Ambient temperature Ta in °C.
  • Junction temperature Tj in °C.
  • Junction-to-case θjc in °C/W.
  • Case-to-heat-sink θcs in °C/W.
  • Heat-sink-to-ambient θsa in °C/W.

Formula

Maximum power = (tj-ta)/(rjc+rcs+rsa).

Heat flow = (tj-ta)/(rjc+rcs+rsa)*3.412142.

Worked example

With ambient temperature Ta 25 °C, junction temperature Tj 25 °C, junction-to-case θjc 10 °C/W, case-to-heat-sink θcs 10 °C/W, heat-sink-to-ambient θsa 10 °C/W in Maximum power mode, the calculator gives maximum power = 0 W; heat flow = 0 BTU/h.

How to read the result

The main result is the maximum power, shown after you click Calculate; the copy button next to it copies the value. Additional results: heat flow.