Dynamisk höjd
Velocity head h = v²/(2g), with v = 4Q/(πD²) and g = 9.81 m/s² as in the original.
Velocity head h = v²/(2g), with v = 4Q/(πD²) and g = 9.81 m/s² as in the original. This is velocity head only, not total pump dynamic head: elevation, pressure difference and friction losses are not included. Exact volume/length unit conversions replace the old rounded factors.
About this calculator
Velocity head h = v²/(2g), with v = 4Q/(πD²) and g = 9.81 m/s² as in the original. This is velocity head only, not total pump dynamic head: elevation, pressure difference and friction losses are not included. Exact volume/length unit conversions replace the old rounded factors.
What you need
- Volume flow rate; the unit box converts between m³/s, m³/h, L/s, L/min, US gal/min, UK gal/min, ft³/min (minimum 0).
- Internal pipe diameter; the unit box converts between m, cm, mm, in, ft.
Formula
Velocity head = (4*Q/(pi*D^2))^2/(2*9.81).
Worked example
With volume flow rate 5 m³/s, internal pipe diameter 2 m in Velocity head from flow rate mode, the calculator gives velocity head = 0.1291 m.
How to read the result
The main result is the velocity head, shown after you click Calculate; the copy button next to it copies the value.