Hydraulic Accumulator Sizing Calculator


Size a gas-loaded (bladder or piston) accumulator: from the oil volume it must deliver between the maximum and minimum working pressures, the precharge, and whether the cycle is slow (isothermal) or fast (adiabatic).

Enter pressures as gauge; the tool converts to absolute internally.

Ange dina värden:
Resultat:

How it works

The gas follows pVn = constant. The deliverable oil volume is ΔV = V(0)·[(p(0)/p(1))1/n − (p(0)/p(2))1/n], so the bottle size is V(0) = ΔV / [(p(0)/p(1))1/n − (p(0)/p(2))1/n] with all pressures absolute (gauge + 1.013 bar). Use n = 1 for slow cycles (over about a minute) and n = 1.4 for fast ones.

  • Precharge to 0.85-0.95 of the minimum working pressure so the bladder never fully empties.
  • Bladder accumulators prefer p(2)/p(1) below 4:1; pistons tolerate more.
  • Round up to the next standard bottle size and recheck the delivered volume.

For emergency power packs and pulsation damping the same equations apply with the relevant ΔV and cycle speed.