Melt Flow Rate Calculator (MFR / MVR)


Melt mass-flow rate (MFR/MFI) and melt volume-flow rate (MVR) from the timed extrudate sample of a plastometer test.

Enter the collected extrudate mass (or volume) and the collection time in seconds.

MFR (mass)

Ange dina värden:
g
s

Common cut intervals are 30, 60, 180 or 300 s; 600 s if collected over the full 10 min.

Resultat:
g/10 min

How it works

MFR (g/10 min) = extrudate mass (g) × 600 / collection time (s). MVR (cm³/10 min) = extrudate volume (cm³) × 600 / collection time (s). If the sample was collected over exactly 10 minutes, the collected value is the result directly.

  • The result is only valid for the exact test conditions used: plastometer temperature, load, die and procedure per ISO 1133-1 / ASTM D1238. Always quote them with the value.
  • MFR is an empirical test value, not a fundamental viscosity and not a direct predictor of full-scale processing behaviour.
  • Do not convert MFR to MVR (or back) without a melt density measured or specified for the test conditions.

Standardised test calculation per ISO 1133-1:2022 and ASTM D1238; the method owns the conditions.