About this calculator

Calculated osmolality adds up the main osmoles in blood: sodium (with its anions), glucose and urea. When measured osmolality is higher by a lot, something else is in the blood, such as methanol, ethylene glycol, isopropanol or mannitol.

What you need

  • Sodium in mEq/L, typically 135 to 145.
  • Glucose in mg/dL or mmol/L; fasting is roughly 70 to 100 mg/dL.
  • Blood urea nitrogen in mg/dL (or urea in mmol/L), typically 7 to 20 mg/dL.
  • Measured osmolality from the laboratory, optional, needed only for the gap; it is usually done by freezing-point depression.

Formula

Calculated osmolality (mOsm/kg) = 2 x Na + glucose / 18 + BUN / 2.8, with glucose and BUN in mg/dL.

Osmolal gap = measured osmolality - calculated osmolality.

Frequently asked questions

What raises the osmolal gap?

Unmeasured osmoles: toxic alcohols such as methanol and ethylene glycol, isopropanol, mannitol, glycerol and others. The clinical setting decides which to suspect.

Does a normal gap rule out toxic alcohol ingestion?

No. Early after ingestion the parent alcohol may not yet have accumulated, and late after ingestion it may already be metabolized. The gap is a clue, not a screen with perfect sensitivity.

Reference values

Normal serum osmolality is about 275 to 295 mOsm/kg. An osmolal gap under about 10 is usually considered normal; reference limits vary by laboratory and formula.

Worked example

Na 140, glucose 90 mg/dL, BUN 14 mg/dL: 280 + 5 + 5 = 290 mOsm/kg.

Common mistakes

  • Forgetting that ethanol contributes osmoles and is absent from the common formula; a patient with alcohol on board can have a misleading gap.
  • Mixing mmol/L and mg/dL between glucose and BUN; enter each in its own unit box.
  • Comparing gaps computed with different published formulas as if they were interchangeable.

Limitations

The common formula omits ethanol and other osmoles. Several alternative formulas exist, so the gap depends on which one is used.

Reference

  • Dorwart WV, Chalmers L. Comparison of methods for calculating serum osmolality from chemical concentrations, and the prognostic value of such calculations. Clin Chem 1975;21(2):190-194.

Disclaimer. Medical information only. This calculator is an educational aid for clinicians and students. It does not give medical advice, diagnosis or treatment, and it does not replace clinical judgment. Check results against the original source and local protocols before using them in patient care.