Power System Load Flow Calculator (2-Bus Line)


A closed-form two-bus load flow: given the receiving-end voltage, load and line impedance, find the sending-end voltage, voltage regulation, line current, losses and transmission efficiency. Per-phase equivalent of a balanced three-phase line.

Enter receiving-end (load-end) data and line R, X.

请输入数值:
结果:

How it works

Exact two-bus solution on the per-phase equivalent: V(s) = √[(V(r) + (P·R + Q·X)/V(r))² + ((P·X − Q·R)/V(r))²] with P, Q per phase. Regulation = (V(s)−V(r))/V(r). Line current from the per-phase apparent power; losses = 3I²R.

  • Balanced three-phase, short-to-medium line; shunt capacitance is ignored (acceptable up to roughly 80 km).
  • Q positive = inductive (lagging) load; enter a negative Q for a capacitive load, which can make regulation negative (Ferranti-like rise).
  • For a leading-pf or very long line use a π-model or a full Newton-Raphson study.

Single-line study only. Multi-bus systems need iterative Newton-Raphson or fast-decoupled power flow software.