Thermal Bridge Heat Loss Calculator


Add up the extra heat loss from thermal bridges: linear bridges (junctions, corners, edges) from psi-values times length, and point bridges (fasteners, brackets) from chi-values, then see their share of the total transmission loss.

Enter up to three linear bridge types, point bridges, and the plain-element loss for context.

请输入数值:
结果:

How it works

Linear thermal bridges: Q = ψ × L × ΔT; point bridges: Q = χ × n × ΔT. Their sum is the extra transmission loss on top of the plain U×A elements.

  • Typical ψ-values: well-detailed junctions 0.02-0.1, ordinary details 0.1-0.3, poor or uninsulated junctions 0.4-1.0 W/mK. Catalogue values come from ISO 10211 calculations or approved detail libraries.
  • Thermal bridges commonly add 10-30% to the transmission loss of a well-insulated envelope - check the share above.
  • Bridges also create cold spots: combine with the condensation risk calculator using the higher local U.

Steady-state sum per ISO 10211 / ISO 14683 conventions. Detailed junctions need 2D/3D thermal modelling for exact psi-values.