Manning's Equation Calculators
Manning relation v = R^(2/3)√S/n with SI base units and coefficient 1. R = flow area / wetted perimeter; S is dimensionless energy slope, not an angle or percentage. Corrects the old 0.66 exponent and rounded US coefficient 1.49. Length and velocity inputs convert to SI before solving; n uses the SI convention. Intended for steady uniform open-channel flow, not pressurized-pipe design.
Calculate Manning's Roughness Coefficient
Calculate Flow Velocity
Calculate Hydraulic Radius
Calculate Line Slope