Reduced Seated Valves and Fittings Calculator


Head-loss coefficients can only be added after conversion to one reference velocity. With β = dseat/dpipe, continuity gives vseat/vpipe =1/β², so the seat contribution is Kseat/β⁴. Here Kr and Ke MUST already be based on pipe velocity: Ktotal = Kr + Ke + Kseat/β⁴. Convert manufacturer data to that basis first; do not mix seat- and pipe-referenced coefficients. The old parseInt truncation and expression (Kr+Kseat)/(β⁴+Ke) are not retained. This is a coefficient-reference calculation, not a validated valve selection or pressure rating.

Enter your values:
Results: