Stair Calculator (Rise, Run and Code Check)
Stair layout from the total rise: number of risers and treads, exact riser height, tread depth, total run and stringer length, checked against the IRC limits (max 7-3/4 in rise, min 10 in run).
Measure the total rise from finished floor to finished floor.
How it works
Risers = total rise ÷ target riser height, rounded to a whole number; the actual riser is the rise divided evenly. Treads = risers − 1 (the top landing is the last step). Total run = treads × tread depth; stringer = √(rise² + run²).
- IRC (residential): riser max 7-3/4 in, tread min 10 in, with max 3/8 in variation between any two risers or treads in a flight. Commercial (IBC) is stricter: 7 in / 11 in.
- Comfort rule of thumb: 2 × riser + tread should land between 24 and 25 in.
- Headroom must stay at least 6 ft 8 in above every tread nosing.
The check shown is the basic IRC geometry only. Guards, handrails, landings, winder rules and local amendments are not covered - confirm with your building department.