| Code for Designation | Grades | Tensile strength Min. kgf/mm2 | Transverse Test | Typical Applications | ||
|---|---|---|---|---|---|---|
| Breaking load Min,kgf | Corresponding transverse rupture stress kgf/mm2 | Deflection Min,mm | ||||
| FG 15 | 15 | 15 | 800 | 34.0 | 4.0 | General structural purposes. |
| FG 20 | 20 | 20 | 900 | 38.2 | 4.5 | |
| FG 25 | 25 | 25 | 1000 | 42.4 | 5.0 | Severe strains e.g. cylinder parts. |
| FG 30 | 30 | 30 | 1100 | 46.7 | 5.5 | |
| FG 35 | 35 | 35 | 1350 | 57.3 | 5.5 | Extra ordinary use. |
| FG 40 | 40 | 40 | 1500 | 63.7 | 5.5 | |