| Grades | Tensile strength (for wire dia upto 7 mm) Min | C % | Si % | Cr % | Va % | Applications |
|---|---|---|---|---|---|---|
| 1 S | 150 | 0.45-0.55 | 0.15-0.35 | 0.90-1.20 | 0.15-0.30 | Cold formed helical springs, volute springs, etc. |
| 1 D | 145 | 0.45-0.55 | 0.15-0.35 | 0.90-1.20 | 0.15-0.30 | |
| 2 S | 175 | 0.50-0.60 | 1.20-1.60 | 0.50-0.80 | - | |
| 2 D | 175 | 0.50-0.60 | 1.20-1.60 | 0.50-0.80 | - | |
| S = Static stressed springs, D = Dynamic stressed springs | ||||||