Differenzdruck


Work out k value.

K = pi^2 rho d^4 dP / (8 W^2) for a restriction passing mass flow W at differential pressure dP (dP = K rho v^2 / 2, v = 4W/(pi rho d^2)). SI base units are used internally.

Find K value

Geben Sie Ihre Werte ein:
kg/m^3
Ergebnisse:

About this calculator

K = pi^2 rho d^4 dP / (8 W^2) for a restriction passing mass flow W at differential pressure dP (dP = K rho v^2 / 2, v = 4W/(pi rho d^2)). SI base units are used internally.

It has 2 modes: Find K value, Find pressure change. Pick the tab for the quantity you want.

What you need

  • Change in pressure; the unit box converts between bar, Pa, kPa, psi.
  • Pipe diameter; the unit box converts between mm, m, in.
  • Fluid density in kg/m^3.
  • Mass flow rate; the unit box converts between kg/hr, kg/s, lb/hr.

Formula

K value = pi^2*rho*d^4*dP/(8*W^2).

Worked example

With change in pressure 100 bar, pipe diameter 2 mm, fluid density 10 kg/m^3, mass flow rate 70 kg/hr in Find K value mode, the calculator gives k value = 5.2208.

How to read the result

The main result is the k value, shown after you click Calculate; the copy button next to it copies the value.