Перепад давления
Work out k value.
K = pi^2 rho d^4 dP / (8 W^2) for a restriction passing mass flow W at differential pressure dP (dP = K rho v^2 / 2, v = 4W/(pi rho d^2)). SI base units are used internally.
About this calculator
K = pi^2 rho d^4 dP / (8 W^2) for a restriction passing mass flow W at differential pressure dP (dP = K rho v^2 / 2, v = 4W/(pi rho d^2)). SI base units are used internally.
It has 2 modes: Find K value, Find pressure change. Pick the tab for the quantity you want.
What you need
- Change in pressure; the unit box converts between bar, Pa, kPa, psi.
- Pipe diameter; the unit box converts between mm, m, in.
- Fluid density in kg/m^3.
- Mass flow rate; the unit box converts between kg/hr, kg/s, lb/hr.
Formula
K value = pi^2*rho*d^4*dP/(8*W^2).
Worked example
With change in pressure 100 bar, pipe diameter 2 mm, fluid density 10 kg/m^3, mass flow rate 70 kg/hr in Find K value mode, the calculator gives k value = 5.2208.
How to read the result
The main result is the k value, shown after you click Calculate; the copy button next to it copies the value.