Nivå 3


30 reviewed questions. Choose answers, then Calculate. Clear resets all selections. Unanswered questions score zero and remain in the percentage denominator. Open the answer review below for sources.

Ange dina värden:
Resultat:
%

Answers and sources

Reviewed 17 November 2026. Ambiguous, malformed and unverified legacy questions have been removed. Wording and answer choices have been corrected where needed. This is a study quiz, not certification of engineering or laboratory decisions.

Question 1: answer and source

According to Unwin's formula, if t is thickness of the plate in mm, the nominal diameter of the rivet is

Answer: d = 6.05 Sqrt(t)

Post-publish correction 2026-11-17: Unwin formula is d = 6.05 x sqrt(t) mm (French formula d = 1.5t + 4). Legacy options contained only 1.91-family values (misprint); replaced the option set and keyed 6.05 sqrt(t).

Source 1

Question 2: answer and source

The slenderness ratio of a column is zero when its length

Answer: is supported on all sides throughout its length

When the member is supported all along, its effective buckling length is zero, so the slenderness ratio is zero. Legacy key 'between the points of zero moments' was wrong.

Source 1

Question 3: answer and source

According to IS 800, lacing bars resist transverse shear equal to

Answer: 2.5% of the axial load

IS 800 designs lacings for a transverse shear of 2.5% of the axial force in the member; stem punctuation cleaned; key unchanged.

Source 1

Question 4: answer and source

When the length of tension member is too long

Answer: a wire is used

Very long tension members (e.g. suspension cables) use wires/wire ropes. Legacy key 'a bar is used' was wrong.

Source 1

Question 5: answer and source

A major beam on a building structure, is known as

Answer: all the above

Girder, floor beam and main beam all denote the major beam; key unchanged.

Source 1

Question 6: answer and source

For simply supported beams, the maximum permitted deflection is

Answer: 1/325 of the span

IS 800:1984 deflection limits: 1/325 of span for simply supported steel beams; key unchanged.

Source 1

Question 7: answer and source

In a fillet weld placed on the sides of the base, the metal experiences

Answer: all the above

A fillet weld group can experience shear, tension and compression depending on loading, though it is designed on shear; key unchanged.

Source 1

Question 8: answer and source

Steel is efficiently used in

Answer: under reinforced section

In an under-reinforced section the steel yields before the concrete crushes, so its full strength is used; key unchanged.

Source 1

Question 9: answer and source

The maximum area of tension reinforcement in a beam is

Answer: 4% of bD

IS 456 clause 26.5.1.1 caps beam reinforcement at 4% of bD; key unchanged.

Source 1

Question 10: answer and source

The large moment of resistance of T-beam section is due to

Answer: composite action between the flanges and the rib

The flange and rib act compositely, giving the T-beam its large moment of resistance; key unchanged.

Source 1

Question 11: answer and source

If in any given plane, one end of a column is unrestrained, its unsupported length l, shall not exceed

Answer: 100 b^2 /D

IS 456 clause 25.3.2: not more than 60b, or 100b^2/D where D is the depth of the cross-section. Stem typo corrected ('pane' to 'plane'); key unchanged.

Source 1

Question 12: answer and source

The diameter of lateral ties in a column shall not be less than

Answer: 6 mm

IS 456:2000 clause 26.5.3.2(c): lateral tie diameter at least one-fourth of the largest longitudinal bar and in no case less than 6 mm. Legacy key '5 mm' was the superseded IS 456:1978 value.

Source 1

Question 13: answer and source

The bending moment at a section of a beam is given by wx^3/6 then the expression for the rate of loading is

Answer: wx

Rate of loading = d2M/dx2 = d2(wx^3/6)/dx2 = wx (wx^2/2 is the shear force, not the loading). Legacy key 'wx^2/2' was wrong.

Source 1

Question 14: answer and source

The torque produced in a circular shaft rotating at 100 r.p.m. to produce 1 h.p. is _____ Kgcm

Answer: 716.2

T = 71620 x HP / N = 71620 x 1 / 100 = 716.2 kg-cm; key unchanged.

Source 1

Question 15: answer and source

The weight of foundation may be assumed to be

Answer: 10% of the column loads

Foundation (plus backfill) weight is conventionally taken as about 10% of the column load; key unchanged.

Source 1

Question 16: answer and source

In a continuous footing the area of longitudinal reinforcement required in the direction of wall is

Answer: 0.3%

Textbook practice for continuous (wall) footings: longitudinal steel 0.3% of the section; key unchanged.

Source 1

Question 17: answer and source

The net upward pressure on footing p is given by

Answer: W.q./W + W1

With soil capacity q, column load W and footing weight W1: area A = (W+W1)/q, so net upward pressure = W/A = Wq/(W+W1); key unchanged.

Source 1

Question 18: answer and source

Partial safety factor m for steel in limit state design is

Answer: 1.15

IS 456 clause 36.4.2.1: gamma_m = 1.15 for steel (1.5 for concrete); key unchanged.

Source 1

Question 19: answer and source

The design strength of materials Fs is given by

Answer: f/Rm

Design strength = characteristic strength / partial safety factor (f/gamma_m); key unchanged.

Source 1

Question 20: answer and source

The pre-stressed concrete induces artificially _____ stress in a structure before it is loaded

Answer: compressive

Prestressing pre-compresses the concrete so service loads first cancel that compression. Legacy key 'bending' was wrong.

Source 1

Question 21: answer and source

According to IS code the total amount of shrinkage for a post tensioned member is taken as

Answer: 2 x 10^-4 / log10 (T+2)

IS 1343 clause 5.2.4.1: shrinkage strain for post-tensioned members = 0.0002 / log10(t+2). Legacy option A had a misprint ('10^4') and the legacy key '2 x 10^-3 / log10 (T+3)' was wrong; option corrected and re-keyed.

Source 1

Question 22: answer and source

The state at which tendon force is released permanently on the concrete is called

Answer: Transfer

Transfer is the stage when the tendon force passes permanently into the concrete. Legacy key 'Pre-tensioning' was wrong.

Source 1

Question 23: answer and source

In a thin cylindrical shell if F1 is the hoop stress and F2 is the longitudinal stress induced, maximum shear stress at any point of the material is given by

Answer: F1 - F2 / 2

Maximum in-plane shear stress = (sigma1 - sigma2)/2 = (F1 - F2)/2. Legacy key '(F1 + F2)/2' was wrong.

Source 1

Question 24: answer and source

A beam is fixed at one end and is supported at the other end to the level of the fixed end by means of a rigid prop. At the propped end, for any applied load

Answer: the flexural moment as well as deflection is zero

A simple support offers no moment restraint (moment zero) and the rigid prop prevents settlement (deflection zero); only the slope is free. Legacy key 'only flexural moment is zero' was incomplete and wrong.

Source 1

Question 25: answer and source

The thickness of lacing bar used in steel ties should not be less than

Answer: L/40

IS 800 clause 7.6.3: lacing flat thickness at least 1/40 of its effective length between connections (single lacing). Legacy key '4.5 mm' was wrong.

Source 1

Question 26: answer and source

Mohr's theorem I gives _____ between two tangents on the elastic line of beams

Answer: Slope

The first moment-area theorem gives the change of slope between two tangents to the elastic curve (area of the M/EI diagram). Legacy key 'B.M.' was wrong.

Source 1

Question 27: answer and source

IS code of practice for steel is

Answer: 800

IS 800 is the code for general construction in steel; key unchanged.

Source 1

Question 28: answer and source

Select cash/commercial crop from the following

Answer: Cotton

Cotton is grown for sale as a fibre crop, i.e. a cash crop; key unchanged.

Source 1

Question 29: answer and source

Canal lining

Answer: Decreases water logging area

Lining cuts seepage from the canal, which reduces the rise of the water table and hence water logging; key unchanged.

Source 1

Question 30: answer and source

The diameter of transverse reinforcement of columns should be equal to 1/4 of the diameter of the main steel rods but not less than

Answer: 6 mm

IS 456:2000 clause 26.5.3.2(c): not less than one-fourth of the largest bar diameter and in no case less than 6 mm. Legacy key '7 mm' was wrong.

Source 1

Change log: 17 November 2026

Original question numbers and review decisions
  • Original Q1: verified as keyed. Post-publish correction 2026-11-17: Unwin formula is d = 6.05 x sqrt(t) mm (French formula d = 1.5t + 4). Legacy options contained only 1.91-family values (misprint); replaced the option set and keyed 6.05 sqrt(t).
  • Original Q2: corrected. When the member is supported all along, its effective buckling length is zero, so the slenderness ratio is zero. Legacy key 'between the points of zero moments' was wrong.
  • Original Q3: verified as keyed. IS 800 designs lacings for a transverse shear of 2.5% of the axial force in the member; stem punctuation cleaned; key unchanged.
  • Original Q4: corrected. Very long tension members (e.g. suspension cables) use wires/wire ropes. Legacy key 'a bar is used' was wrong.
  • Original Q5: verified as keyed. Girder, floor beam and main beam all denote the major beam; key unchanged.
  • Original Q6: verified as keyed. IS 800:1984 deflection limits: 1/325 of span for simply supported steel beams; key unchanged.
  • Original Q8: verified as keyed. A fillet weld group can experience shear, tension and compression depending on loading, though it is designed on shear; key unchanged.
  • Original Q9: verified as keyed. In an under-reinforced section the steel yields before the concrete crushes, so its full strength is used; key unchanged.
  • Original Q10: verified as keyed. IS 456 clause 26.5.1.1 caps beam reinforcement at 4% of bD; key unchanged.
  • Original Q11: verified as keyed. The flange and rib act compositely, giving the T-beam its large moment of resistance; key unchanged.
  • Original Q12: corrected. IS 456 clause 25.3.2: not more than 60b, or 100b^2/D where D is the depth of the cross-section. Stem typo corrected ('pane' to 'plane'); key unchanged.
  • Original Q13: verified as keyed. IS 456:2000 clause 26.5.3.2(c): lateral tie diameter at least one-fourth of the largest longitudinal bar and in no case less than 6 mm. Legacy key '5 mm' was the superseded IS 456:1978 value.
  • Original Q14: corrected. Rate of loading = d2M/dx2 = d2(wx^3/6)/dx2 = wx (wx^2/2 is the shear force, not the loading). Legacy key 'wx^2/2' was wrong.
  • Original Q15: verified as keyed. T = 71620 x HP / N = 71620 x 1 / 100 = 716.2 kg-cm; key unchanged.
  • Original Q16: verified as keyed. Foundation (plus backfill) weight is conventionally taken as about 10% of the column load; key unchanged.
  • Original Q17: verified as keyed. Textbook practice for continuous (wall) footings: longitudinal steel 0.3% of the section; key unchanged.
  • Original Q18: verified as keyed. With soil capacity q, column load W and footing weight W1: area A = (W+W1)/q, so net upward pressure = W/A = Wq/(W+W1); key unchanged.
  • Original Q19: verified as keyed. IS 456 clause 36.4.2.1: gamma_m = 1.15 for steel (1.5 for concrete); key unchanged.
  • Original Q20: verified as keyed. Design strength = characteristic strength / partial safety factor (f/gamma_m); key unchanged.
  • Original Q21: corrected. Prestressing pre-compresses the concrete so service loads first cancel that compression. Legacy key 'bending' was wrong.
  • Original Q22: corrected. IS 1343 clause 5.2.4.1: shrinkage strain for post-tensioned members = 0.0002 / log10(t+2). Legacy option A had a misprint ('10^4') and the legacy key '2 x 10^-3 / log10 (T+3)' was wrong; option corrected and re-keyed.
  • Original Q23: corrected. Transfer is the stage when the tendon force passes permanently into the concrete. Legacy key 'Pre-tensioning' was wrong.
  • Original Q24: corrected. Maximum in-plane shear stress = (sigma1 - sigma2)/2 = (F1 - F2)/2. Legacy key '(F1 + F2)/2' was wrong.
  • Original Q25: corrected. A simple support offers no moment restraint (moment zero) and the rigid prop prevents settlement (deflection zero); only the slope is free. Legacy key 'only flexural moment is zero' was incomplete and wrong.
  • Original Q26: corrected. IS 800 clause 7.6.3: lacing flat thickness at least 1/40 of its effective length between connections (single lacing). Legacy key '4.5 mm' was wrong.
  • Original Q27: corrected. The first moment-area theorem gives the change of slope between two tangents to the elastic curve (area of the M/EI diagram). Legacy key 'B.M.' was wrong.
  • Original Q28: verified as keyed. IS 800 is the code for general construction in steel; key unchanged.
  • Original Q29: verified as keyed. Cotton is grown for sale as a fibre crop, i.e. a cash crop; key unchanged.
  • Original Q30: verified as keyed. Lining cuts seepage from the canal, which reduces the rise of the water table and hence water logging; key unchanged.
  • Original Q31: corrected. IS 456:2000 clause 26.5.3.2(c): not less than one-fourth of the largest bar diameter and in no case less than 6 mm. Legacy key '7 mm' was wrong.
  • Original Q7: The correct value is 7 (IS 456 clause 23.2.1 basic span/effective-depth ratio for cantilevers), but 7 is not among the legacy options (4, 8, 12, 16), and the keyed 12 has no code basis. Dropped as unfixable.