Pertes de charge singulières
Head loss in fittings.
Head loss in fittings: HL = K V^2 / (2 g), where K is the loss coefficient, V the flow velocity and g the acceleration of gravity (9.80665 m/s^2 default).
About this calculator
Head loss in fittings: HL = K V^2 / (2 g), where K is the loss coefficient, V the flow velocity and g the acceleration of gravity (9.80665 m/s^2 default).
It has 3 modes: Calculate head loss, Calculate velocity, Calculate loss coefficient. Pick the tab for the quantity you want.
What you need
- Loss coefficient (K) (minimum 0).
- Velocity (V); the unit box converts between m/s, ft/s, cm/s, mm/s, in/s, km/s, yd/s, mile/s, mile/h, knot, cm/h, in/h, ft/day, m/day (minimum 0).
- Acceleration of gravity; the unit box converts between m/s^2, ft/s^2, cm/s^2, mm/s^2, in/s^2, km/s^2, yd/s^2, mile/s^2.
Formula
Head loss = K*V^2/(2*g).
Worked example
With loss coefficient (K) 10, velocity (V) 10 m/s, acceleration of gravity 10 m/s^2 in Calculate head loss mode, the calculator gives head loss = 50 m.
How to read the result
The main result is the head loss, shown after you click Calculate; the copy button next to it copies the value.