In the working stress method, the depth of the critical (balanced) neutral axis of a singly reinforced beam is _____ (m = modular ratio, r = ratio of permissible stress in steel to permissible stress in concrete, d = effective depth)

Answer: (m x d) / (m + r)

WSM balanced section: x_c = k.d with k = m.sigma_cbc/(m.sigma_cbc + sigma_st) = m/(m+r) when r = sigma_st/sigma_cbc, so x_c = (m.d)/(m+r). Stem clarified to define m, r and d; key unchanged.

Source 1

Question 2: answer and source

As per IS 456, the minimum horizontal spacing between parallel main reinforcement bars of the same size should not be less than _____ diameters (or 5 mm more than the nominal maximum size of coarse aggregate, if greater)

Answer: 1

IS 456:2000 cl 26.3.1(a): minimum horizontal distance between parallel main bars = bar diameter (equal sizes), or 5 mm more than the nominal maximum aggregate size if greater. Legacy key '2 diameters' wrong; correct is 1. Stem reworded to state the aggregate-size condition.

Source 1

Question 3: answer and source

Rapid hardening cement is actually early _____ cement

Answer: strength

Rapid-hardening cement sets in about the same time as OPC but develops high EARLY STRENGTH ('High Early Strength Cement'). Legacy key 'setting' wrong.

Source 1

Question 4: answer and source

Ductility of steel decreases with a percentage _____ of carbon steel

Answer: increase

Increasing carbon content raises strength but lowers ductility of steel.

Source 1

Question 5: answer and source

_____ ratio of steel, within elastic limit, varies from 0.25 to 0.33

Answer: Poisson's

Poisson's ratio of structural steel is about 0.3 (commonly quoted range 0.25-0.33 within the elastic limit).

Source 1

Question 6: answer and source

The process of adding extra carbon to the surface of steel is known as _____

Answer: Carburising

Diffusing carbon into the surface of low-carbon steel is carburising (case hardening). Legacy key 'Carbon treatement' wrong and non-standard.

Source 1

Question 7: answer and source

Maximum shear force occurs at the edge of a base plate in a _____ footing

Answer: Grillage

In a grillage footing 'the maximum shear force develops at the edge of the base plate'. Legacy key 'Rectangular' wrong; correct is Grillage.

Source 1

Question 8: answer and source

As per IS : 456 in a two-way slab, the width of the middle strip along each span should be

Answer: 3/4 of width of the span in that direction

Two-way slab design: middle strips three-quarters of the panel width carry the Annex D moments, edge strips one-eighth each.

Source 1 Source 2

Question 9: answer and source

The reinforcement provided in the form of ties or stirrups or binders in a column is known as

Answer: transverse reinforcement

IS 456:2000 cl 26.5.3: ties/helical binding in a column are the column's transverse reinforcement.

Source 1

Question 10: answer and source

Load carrying capacity of long columns are less as compared to short columns due to

Answer: buckling effect of columns

Long (slender) columns lose capacity through buckling - Euler's critical load falls with slenderness.

Source 1

Question 11: answer and source

As per IS : 456 the thickness of footing edge on soils should not be less than

Answer: 15 cm

IS 456:2000 cl 34.1.2: thickness at the edge of a footing on soil shall not be less than 150 mm (15 cm).

Source 1

Change log: 17 November 2026

Original question numbers and review decisions
  • Original Q1: corrected. WSM balanced section: x_c = k.d with k = m.sigma_cbc/(m.sigma_cbc + sigma_st) = m/(m+r) when r = sigma_st/sigma_cbc, so x_c = (m.d)/(m+r). Stem clarified to define m, r and d; key unchanged.
  • Original Q2: corrected. IS 456:2000 cl 26.3.1(a): minimum horizontal distance between parallel main bars = bar diameter (equal sizes), or 5 mm more than the nominal maximum aggregate size if greater. Legacy key '2 diameters' wrong; correct is 1. Stem reworded to state the aggregate-size condition.
  • Original Q3: dropped. The cited code also limits loading class to 3 kN/m2; that condition is absent. Drop rather than silently add it.
  • Original Q4: dropped. A ribbed slab does not necessarily provide a plain ceiling or all listed insulation benefits; one MCQ page does not establish the broad claim.
  • Original Q5: dropped. Rule of thumb ('max BM when water depth = half the short wall') could not be confirmed against any reputable design source after targeted searches; excluded per verification-only policy.
  • Original Q6: corrected. Rapid-hardening cement sets in about the same time as OPC but develops high EARLY STRENGTH ('High Early Strength Cement'). Legacy key 'setting' wrong.
  • Original Q7: dropped. The cited stair-design source could not be read (403); the numerical rule is not established by inspected evidence.
  • Original Q8: verified. Increasing carbon content raises strength but lowers ductility of steel.
  • Original Q9: verified. Poisson's ratio of structural steel is about 0.3 (commonly quoted range 0.25-0.33 within the elastic limit).
  • Original Q10: dropped. Slenderness uses effective length, but only unsupported length is stated and end restraint is absent.
  • Original Q11: corrected. Diffusing carbon into the surface of low-carbon steel is carburising (case hardening). Legacy key 'Carbon treatement' wrong and non-standard.
  • Original Q12: dropped. The generic metal-hardening claim is broader than the steel carburising source supports.
  • Original Q13: corrected. In a grillage footing 'the maximum shear force develops at the edge of the base plate'. Legacy key 'Rectangular' wrong; correct is Grillage.
  • Original Q14: dropped. IS 800 Table 3 applies the 350 limit to a particular truss/bracing tie not effective under compression, not every reversal case in the stem.
  • Original Q15: dropped. Stem says 0.67L but IS 800:1984 Table 5.2 / IS 800:2007 Table 11 give 0.65L for a member held in position and restrained in direction at both ends. The only fix would be editing the stem so the keyed option fits - a guessed corruption, so dropped per revision rule.
  • Original Q16: dropped. The theoretical Euler L/2 answer is not distinguished from code-design effective length.
  • Original Q17: dropped. Mangled worked example: the source problem is ISA 125x75x10 with 27 mm rivets (this bank says 155x75x10), and the claimed 27 t strength is not reproducible (working-stress calculation gives ~22 t). Data internally inconsistent.
  • Original Q18: dropped. No code deflection limit applies to pure tension members (ties); IS 800 deflection limits cover flexural members (beams, girders, purlins). Key 'L/350' unverifiable.
  • Original Q19: dropped. The cited page resolves to a website-unavailable message; no inspected source supports the retained row.
  • Original Q20: dropped. A single MCQ page is insufficient support for a universal preliminary beam-width rule.
  • Original Q21: dropped. Continuous-beam support moment does not by itself require a doubly reinforced section.
  • Original Q22: dropped. Excluded from release because available support was insufficient.
  • Original Q23: verified. Two-way slab design: middle strips three-quarters of the panel width carry the Annex D moments, edge strips one-eighth each.
  • Original Q24: verified. IS 456:2000 cl 26.5.3: ties/helical binding in a column are the column's transverse reinforcement.
  • Original Q25: verified. Long (slender) columns lose capacity through buckling - Euler's critical load falls with slenderness.
  • Original Q26: verified. IS 456:2000 cl 34.1.2: thickness at the edge of a footing on soil shall not be less than 150 mm (15 cm).
  • Original Q27: dropped. Keyed M200 reflects withdrawn pre-2000 practice; current IS 2911 (Part 1/Sec 1):2010 requires minimum grade M25 for cast-in-situ piles, and M250 is not among the options.
  • Original Q28: dropped. The relation needs constant EI and a sign convention, neither stated.
  • Original Q29: dropped. Extreme free fibres and free edges overlap as answer choices; the linked source was also inaccessible.
  • Original Q30: dropped. Keyed M15 conflicts with IS 3370 minimum grades for liquid-retaining structures (M20 in the 1965 edition, M30 in the 2021 edition); no edition supports M15.