Series and Parallel Pump Operation Calculator


See how two identical pumps behave in series and in parallel against your system curve, compared with a single pump. Pump curves are modelled as H = H(0) − kQ² and the system as H = H(static) + KQ².

Enter the pump curve (shutoff head + rated point) and the system curve.

Saisissez vos valeurs :

Total head the system needs at the design flow, including static.

Résultats :

How it works

Each pump is modelled as H = H(0) − kQ² with k fitted through your rated point. The system curve is H = H(static) + KQ². In series the heads add at the same flow (H(0) and k double); in parallel the flows add at the same head. The operating point is where the combined curve crosses the system curve.

  • Series gains are largest on steep (friction-dominated) systems; parallel gains are largest on flat (static-dominated) systems. Check the gain figures above.
  • Neither arrangement doubles the flow: the system curve decides.
  • Verify each pump still runs near its best efficiency point and within NPSH limits.

Simplified parabolic model. Use the manufacturer's real curves for selection; dissimilar pumps need composite-curve construction.